SEC 3100 Transmitter
Instruction and Operation Manual
Sensor Electronics Corporation
5500 Lincoln Drive
Minneapolis, Minnesota 55436 USA
(952) 938-9486 Fax (952) 938-9617
Web site www.sensorelectronics.com
Part Number 3100-EXP-MANUAL
REV 121107-001
Zobrazit stránku 0
1 2 3 4 5 6 ... 28 29

Shrnutí obsahu

Strany 1 - SEC 3100 Transmitter

SEC 3100 Transmitter Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952

Strany 2

Selecting Enter when the SEC 3100 in in normal operating mode will advance to the following display: Selecting Enter will allow the operator to

Strany 3 - Table of Contents

Main Menu and Sub Menus Enter Calibration Menu EJECT MEMORY CARD INFO * MAIN MENU * CALIBRATION ALA

Strany 4 - I. SPECIFICATIONS

Calibration Menu Enter * CALIBRATION ALARM RELAY Using the Up and Down arrows allows the operator to move the cursor (*) to select

Strany 5 - Installation and Startup

To Span the sensor with calibration gas use the Up and Down arrows to select the following display. Apply span gas to the sensor for the

Strany 6

Alarm Menu Enter CALIBRATION * ALARM RELAY Enter Select the Alarm Relay (LOW, MID, HI) using the down arrow. Once the cursor

Strany 7

Arrow Down Selecting Enter will allow the operator to change the operation of the relay operation from Active HI

Strany 8

Relay Menu CALIBRATION ALARM * RELAY Selecting Enter will advance to the following menu. * LOW MID HI Arrow down

Strany 9 - ID: 1

Select Enter ON DLY LOW * OFF DLY 0 ENERGIZED EXIT Select Enter ON DLY LOW * OFF DLY

Strany 10

Network Menu * NETWORK HIDE Select Enter * ZONE 0 ID ONLINE EXIT Select Enter to change the Zone numbe

Strany 11

Hide Menu NETWORK * HIDE NO Using Enter the operator can toggle between Hide YES and Hide NO. The Hide function allows the oper

Strany 12

Sensor Electronics Corporation Sensor Electronics Corporation (SEC) designs and manufactures innovative fixed system gas detection quality and ser

Strany 13

Time Date Menu SELF TEST * DATE TIME Entering this menu will allow the operator to set the time and date of the SEC 3100 real time

Strany 14

Select Enter * EXIT Selecting Enter again will return the SEC 3100 to normal operation.

Strany 15

Diagnostics Menu * DIAGNOSTICS REST RELAYS EXIT The Diagnostics Menu will allow the operator to enter the Locator Mode and Toggle

Strany 16

Reset Relays Menu DIAGNOSTICS * RESET RELAYS EXIT The Reset Reset relays Menu will allow the operator to reset latched relays. Lat

Strany 17

V. FIGURES Figure 1 – Overall Layout Figure 2 – SEC 3100 Wiring Figure 3 – SEC Sensor Separation Kit Figure 4 – Mounting SEC 3100 and SEC Mill

Strany 18

LCD Display: Real Time Status Gas Type Gas Concentration Fault Identification Range ID Number Memory Card Status Interactive M

Strany 19 - : 1 ID

TB 3 (1) WHITE (DATA/CAL) (2) BLUE OR GREEN (4-20 mA) (3) RED (+24 VDC) (4) BLACK (DC COMMO

Strany 20

SENSOR ELECTRONICS CORPORATION 5500 LINCOLN DRIVE MINNEAPOLIS, MINNESOTA 55436 USA (T) 952.938.9486 (F) 952.938.9617 [email protected] F

Strany 21 - * EXIT

FIGURE 4 SEC 3100 – SEC Millenium Mounting

Strany 22

FIGURE 5 SEC 3100 – SEC 3000 Mounting

Strany 23 - EXIT

Table of Contents I. SPECIFICATIONS II. GENERAL DESCRIPTION III. OPERATION Installation and Startup Fault Codes IV. MAGNETIC

Strany 24 - V. FIGURES

I. SPECIFICATIONS Model: SEC 3100 Transmitter For use with: SEC Millenium and SEC Signature series infrared sensors and SEC 3000 Toxic and Oxy

Strany 25 - ¾ h )

II GENERAL DESCRIPTION CONVENTIONS The following conventions are used in this manual. Warning Statement ! VDC (DC Voltag

Strany 26 - FIGURE 2

rise. In addition, if the temperature of the gas is hotter than ambient air or mixed with gases that are lighter than air, it could also rise. •

Strany 27 - SEC SENSOR SEPARATION KIT

The 4 to 20 mA output of the SEC 3100 sensor is a non-isolated current source. Current Output and Corresponding Status Curren

Strany 28 - FIGURE 4

IV. MAGNETIC SWITCH OPERATION The SEC 3100 has three (3) magnetic switch pickups on the Display PCB. The picture below shows the location of

Strany 29 - SEC 3100 – SEC 3000 Mounting

V. MENU OPERATION Inital Power Up Sequence of the SEC 3100 SYSTEM BOOT PROCESS --- WAIT FOR SYNC –- SYSTEM BOOT PROCESS -WAIT FOR